Production introduction
Foinbo® introduces their water mist fire sprinkler system, designed to provide maximum protection in case of a fire emergency. The system comes in different models, including ZSTMA-T37.5/150, ZSTMA-T42/150, ZSTMB-T52.5/150, ZSTMB-T75/150, ZSTMB-T12.5/120, ZSTMB-T27.5/120, ZSTMB-T50.5/120, and ZSTMB-T80/120.
These fire sprinklers have been engineered to provide effective coverage in a wide range of environments, from industrial premises to high-rise buildings. With their high K factor, the sprinklers provide reliable fire suppression by releasing a fine mist of water that quickly extinguishes the flames.
What's more, the Foinbo® sprinklers are easy to install, making them ideal for retrofitting into existing structures. Their vertical and horizontal spray angles provide flexibility to cater to various design requirements, while their precision engineering ensures they work effectively under high pressure.
Product specification
|
Model Number |
Install |
K Factor |
Spray Angel |
|
ZSTMA-T37.5/150 |
Vertical |
37.5 |
150° |
|
ZSTMA-T42/150 |
Vertical |
42 |
150° |
|
ZSTMB-T52.5/150 |
Vertical |
52.5 |
150° |
|
ZSTMB-T75/150 |
Vertical |
75 |
150° |
|
ZSTMB-T12.5/120 |
Horizontal |
12.5 |
120° |
|
ZSTMB-T27.5/120 |
Horizontal |
27.5 |
120° |
|
ZSTMB-T50.5/120 |
Horizontal |
50.5 |
120° |
|
ZSTMB-T80/120 |
Horizontal |
80 |
120° |
FAQ
Q: What is a water mist sprinkler?
A: A water mist fire sprinkler is a type of fire suppression system that uses a fine mist of water to extinguish or control fires. It works by removing heat from the fire, displacing oxygen and creating a barrier between the fuel and the flames.
Q: What is the install K factor of ZSTMA-T37.5/150?
A: The install K factor of ZSTMA-T37.5/150 is 37.5.
Q: What is the spray angle of ZSTMB-T52.5/150?
A: The spray angle of ZSTMB-T52.5/150 is 150 degrees.
Q: What is the difference between vertical and horizontal water mist fire sprinklers?
A: Vertical mist fire sprinklers are installed on the ceiling and spray downwards while horizontal mist fire sprinklers are installed on the walls and spray horizontally. The choice between the two depends on the layout and design of the building.
Q: What are the advantages of using mist fire sprinklers?
A: Some of the advantages of using mist fire sprinklers include:
- They use less water compared to conventional sprinkler systems, causing less water damage to the building.
- They are more effective in controlling fires quickly, reducing the risk of damage.
- They are environmentally friendly and require less maintenance compared to other fire suppression systems.