Products Introduction
foinbo® Wet Alarm Check Valve for Fire is a purpose-engineered hydraulic control component crafted exclusively for fire protection systems, designed to synchronize water flow management with instant emergency alerting in high-risk facilities. Fabricated from premium ductile iron and rated for 1.6Mpa operational pressure, this valve spans 3" to 8" flange-end configurations compliant with BS4504 standards, making it a universal fit for wet-pipe sprinkler and foam-water hybrid fire systems.
Wet Alarm Check Valve for Fire features a dual-chamber hydraulic design that not only blocks reverse flow to safeguard municipal water supplies from foam mixture contamination but also activates a high-decibel alarm the moment water velocity surpasses the threshold of a single sprinkler head activation-creating an unbreakable link between system operation and emergency response.
Products Parameters
|
Specification |
ZSFZ-Sprinkler System Alarm Check Valve |
||||
|
3" |
4" |
5" |
6" |
8" |
|
|
Rated Operation Pressure |
1.6Mpa |
||||
|
Application Medium |
Water ,Foam mixture |
||||
|
Connection Type |
Flange End |
||||
|
Body Material |
Ductile Iron |
||||
|
Installation |
Vertical |
||||
|
Flange Standard |
BS4504 |
||||
Products Description




Application Detail
- Petrochemical Storage Depots: In facilities storing gasoline, diesel, and chemical solvents, Wet Alarm Check Valve for Fire is paired with foam-water suppression systems. Its 1.6Mpa pressure rating handles the high hydraulic demands of large-scale foam deployment, while the hydraulic alarm ensures on-site fire teams are alerted instantly to fuel spill fires-even in remote storage zones with no electrical power.
- High-Rise Hotel & Resort Towers: For luxury hotels with 30+ floors, this valve regulates water flow in wet-pipe sprinkler systems serving guest rooms, kitchens, and ballrooms. The full-port design ensures water reaches upper-floor sprinklers quickly, and the ductile iron construction withstands the structural settling and pipe vibrations common in tall buildings, keeping Wet Alarm Check Valve for Fire operational for decades.
- Warehouse Distribution Centers with Pallet Racking: In 100,000+ sq. ft. logistics warehouses storing combustible goods, Wet Alarm Check Valve for Fire monitors multiple sprinkler zones simultaneously. Its reverse flow prevention feature keeps foam mixture from cross-contaminating non-fire zones, and the quick-test port allows maintenance teams to verify functionality without interrupting daily warehouse operations.
FAQs
Q: Can Wet Alarm Check Valve for Fire operate without an external power supply for alarm activation?
A: Yes. The alarm system is fully hydraulically actuated, using the pressure of water or foam mixture flow from the fire system to trigger a mechanical alarm bell. This ensures Wet Alarm Check Valve for Fire provides reliable alerts even during complete power failures at the fire scene.
Q: What is the maximum flow rate Wet Alarm Check Valve for Fire can handle without pressure drop?
A: Thanks to its full-port ductile iron design, it supports flow rates up to 1200 L/min (varies by size: 3" = 500 L/min, 8" = 1200 L/min) with a pressure drop of less than 0.05Mpa-critical for ensuring sufficient water/foam reaches large fire zones quickly.
Q: Is Wet Alarm Check Valve for Fire compatible with BS4504 flanges of both PN16 and PN25 pressure ratings?
A: It is fully compatible with both PN16 and PN25 BS4504 flanges. The valve's flange faces are precision-machined to match the sealing dimensions of both pressure classes, simplifying installation in mixed-pressure fire systems and making Wet Alarm Check Valve for Fire highly versatile.
Q: How to resolve air lock in the alarm chamber of Wet Alarm Check Valve for Fire after system maintenance?
A: Open the dedicated air release valve on the alarm chamber and slowly activate the system's test valve until a steady stream of water (no air bubbles) flows from the air release valve. This simple 2-minute process purges air locks, restoring full alarm sensitivity to Wet Alarm Check Valve for Fire.
Q: Does Wet Alarm Check Valve for Fire include a built-in pressure relief function for over-pressurized fire systems?
A: It features an optional factory-installed pressure relief bypass that can be calibrated to open at 1.6Mpa (matching the valve's rated pressure). This accessory protects Wet Alarm Check Valve for Fire and downstream piping from damage caused by system over-pressurization during testing or water hammer events.