Production introduction
Built with a focus on durability and reliability, the Foam Bladder Tank Horizontal Type features a robust carbon - steel outer shell. This construction provides excellent resistance to external impacts, corrosion, and harsh environmental conditions. Inside, a high - quality rubber or PVC bladder serves as the core component, safely storing the foam concentrate and preventing it from coming into direct contact with the tank walls. This separation ensures the integrity and longevity of the foam, safeguarding its fire - suppressing properties over time.
One of the key advantages of the Horizontal Type Foam Bladder Tank is its unique design, which maximizes storage capacity while minimizing floor space requirements. The horizontal orientation allows for easy integration into existing fire - fighting systems, especially in areas with limited vertical space. It also simplifies the installation and maintenance processes, as access to components such as valves, pipes, and the bladder itself is more straightforward compared to vertical tanks.
The tank is equipped with state - of - the - art components, including an SS304 stainless - steel proportioner for precise foam - water mixing. With adjustable mixing ratios of 3% or 6%, it can adapt to different fire - fighting scenarios, ensuring optimal foam generation for effective fire suppression. The ball valve, safety valve, and piping system, available in both carbon - steel and SS304 stainless - steel options, guarantee reliable flow control and safe operation under varying pressure conditions.
Available in a wide range of capacities, from compact models suitable for small - scale applications to large - volume tanks for industrial use, the Foam Bladder Tank Horizontal Type caters to diverse requirements. Its operating pressure range of 0.8 - 1.2 Mpa, combined with a flexible flow - rate range depending on the model, enables efficient foam delivery to combat fires of different magnitudes.
Products Parameters
|
Model |
Capacity |
Description |
Working pressure |
Ratio |
Flow Rate Range |
|
PHYM-1000 |
1000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-1500 |
1500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-2000 |
2000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-2500 |
2500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-3000 |
3000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-3500 |
3500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-4000 |
4000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-4500 |
4500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-5000 |
5000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-5500 |
5500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-6000 |
6000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
16-64 LPS |
|
PHYM-7000 |
7000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
16-64 LPS |
|
PHYM-8000 |
8000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
16-64 LPS |
Products Features
| Body Material |
Carbon Steel; |
| Bladder Material |
Rubber / PVC |
| Proportioner |
SS304 Stainless Steel; |
| Ball Valve |
Carbon Steel is standard,SS304 Stainless Steel optional; |
| Safety Valve |
Carbon Steel is standard,SS304 Stainless Steel optional ; |
| Piping System |
Carbon Steel is standard,SS304 Stainless Steel optional ; |
|
Flange Standard of Proportioner |
ANSI / BS4504 / GB; |
| Surface Finishing | Painting |
Products Description




FAQ
Q: How does the horizontal design of the Foam Bladder Tank affect its stability?
A: The horizontal layout distributes the weight of the tank and its contents more evenly across the ground. This, combined with a wide base and proper anchoring, provides excellent stability. Additionally, the tank's center of gravity is lower compared to vertical tanks, reducing the risk of tipping, even when partially filled or during seismic activity.
Q: Can the Foam Bladder Tank Horizontal Type be installed underground?
A: While it's primarily designed for above - ground use, with proper modifications and protective measures, it can be installed underground. However, this requires careful consideration of factors such as soil conditions, waterproofing for the outer shell, and ensuring easy access for maintenance and inspection.
Q: What impact does sunlight exposure have on the Foam Bladder Tank Horizontal Type?
A: Prolonged exposure to direct sunlight can cause the outer paint finish to fade and may accelerate the degradation of the bladder material over time. To mitigate this, it's recommended to install the tank in shaded areas or use UV - resistant coatings on the tank exterior and consider adding insulation to protect the bladder from heat buildup.
Q: How do you perform a foam - mixing ratio calibration on the tank?
A: Use a calibrated flow meter to measure the water and foam concentrate flow rates. Adjust the settings on the SS304 stainless - steel proportioner according to the desired 3% or 6% ratio. Conduct multiple tests and compare the actual foam output with the expected values, making incremental adjustments until the correct ratio is achieved.
Q: Can the Foam Bladder Tank Horizontal Type be used in mobile firefighting units?
A: Smaller - capacity models can be adapted for use in mobile units with appropriate mounting and securing systems. However, considerations such as weight distribution, shock absorption during transit, and ensuring all components remain functional under varying road conditions need to be addressed for safe and effective operation.