Production introduction
Constructed with a carbon - steel body for structural strength, Vertical / Horizontal Foam Tanks utilize a rubber or PVC bladder to segregate foam concentrate from water, preserving the concentrate's efficacy. The SS304 stainless - steel proportioner ensures accurate dispensing of concentrate at 3% or 6% ratios, a critical factor for generating optimal foam to smother fires. Operating within a 0.8–1.2 Mpa pressure range, these tanks align with ANSI/BS4504/GB flange standards, enabling seamless integration into existing fire - fighting systems.
Vertical models (PHYML - 100 to PHYML - 5500) span 100 L to 5500 L capacities, ideal for facilities where vertical space utilization is preferred. Horizontal models (PHYM - 1000 to PHYM - 8000) offer larger storage (up to 8000 L) and fit well in layouts favoring horizontal configurations. Flow rates ranging from 4–64 LPS allow these tanks to address both minor spills and large - scale industrial fire threats.
Optional SS304 stainless - steel components (ball valves, safety valves, piping) enhance corrosion resistance, making Vertical / Horizontal Foam Tanks suitable for harsh environments. Whether safeguarding fuel terminals, chemical plants, or warehouses, these tanks ensure reliable foam supply for rapid fire response. For fire - safety systems demanding precision, durability, and adaptability, they serve as a foundational element, enabling timely and effective foam deployment to protect assets and lives.
Products Parameters
Vertical Type
|
Model |
Capacity |
Description |
Working pressure |
Ratio |
Flow Rate Range |
|
PHYML-100 |
100 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
4-24 LPS |
|
PHYML-200 |
200 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
4-24 LPS |
|
PHYML-300 |
300 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
4-24 LPS |
|
PHYML-500 |
500 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
4-24 LPS |
|
PHYML-750 |
750 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
4-24 LPS |
|
PHYML-1000 |
1000 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYML-1500 |
1500 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYML-2000 |
2000 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYML-2500 |
2500 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYML-3000 |
3000 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYML-3500 |
3500 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYML-4000 |
4000 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYML-4500 |
4500 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYML-5000 |
5000 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYML-5500 |
5500 L |
Vertical |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
Horizontal Type
|
Model |
Capacity |
Description |
Working pressure |
Ratio |
Flow Rate Range |
|
PHYM-1000 |
1000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-1500 |
1500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-2000 |
2000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-2500 |
2500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
8-32 LPS |
|
PHYM-3000 |
3000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-3500 |
3500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-4000 |
4000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-4500 |
4500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-5000 |
5000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-5500 |
5500 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
12-48 LPS |
|
PHYM-6000 |
6000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
16-64 LPS |
|
PHYM-7000 |
7000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
16-64 LPS |
|
PHYM-8000 |
8000 L |
Horizontal |
0.8-1.2 Mpa |
3% or 6% |
16-64 LPS |
Products Features
| Body Material |
Carbon Steel; |
| Bladder Material |
Rubber / PVC |
| Proportioner |
SS304 Stainless Steel; |
| Ball Valve |
Carbon Steel is standard,SS304 Stainless Steel optional; |
| Safety Valve |
Carbon Steel is standard,SS304 Stainless Steel optional ; |
| Piping System |
Carbon Steel is standard,SS304 Stainless Steel optional ; |
|
Flange Standard of Proportioner |
ANSI / BS4504 / GB; |
| Surface Finishing | Painting |
Products Description




FAQ
Q: Are there specific seismic considerations for installing Vertical / Horizontal Foam Tanks?
A: Yes. In seismic zones, secure vertical tanks with anti - seismic brackets and anchor horizontal tanks to reinforced foundations. Consult local seismic codes and the manufacturer for installation guidelines.
Q: How does the choice of bladder material (rubber vs. PVC) impact tank performance?
A: Rubber bladders offer better elasticity for long - term use, while PVC provides chemical resistance. Select based on the foam concentrate type and environmental conditions-aggressive concentrates may require PVC.
Q: Can Vertical / Horizontal Foam Tanks be monitored remotely for concentrate levels?
A: Yes, by installing level sensors (e.g., ultrasonic or float - type) connected to a SCADA system. This allows remote tracking of concentrate levels for timely refills.
Q: What maintenance is required for the external painting of these tanks?
A: Inspect paint annually for chipping or corrosion. Reapply paint every 3–5 years, or as needed, to protect the carbon - steel body from environmental damage.
Q: How to determine the right tank orientation (vertical vs. horizontal) for a facility?
A: Calibrate annually or after major system maintenance. Use a calibrated flow meter to verify the 3%/6% ratio-incorrect proportioning reduces foam effectiveness.