Production introduction
A defining attribute of Low Expansion Foam Chambers is their low - expansion capability (≥5 times), which generates a dense, persistent foam blanket to smother fires efficiently. The 25% liquid drain time of ≥120s ensures prolonged foam retention, enhancing fire - fighting effectiveness by preventing rapid foam collapse. Available in four vertical models-PCL4, PCL8, PCL16, and PCL24-these Low Expansion Foam Chambers cater to diverse flow requirements:
PCL4: 240 LPM flow, 2″ inlet/2.5″ outlet
PCL8: 480 LPM flow, 2.5″ inlet/3″ outlet
PCL16: 960 LPM flow, 4″ inlet/5″ outlet
PCL24: 1440 LPM flow, 5″ inlet/6″ outlet
Whether safeguarding petroleum storage tanks, chemical reservoirs, or industrial bulk - storage vessels, Low Expansion Foam Chambers deliver reliable, targeted suppression. Their carbon - steel construction resists mechanical wear, while standardized flanges simplify installation. For industries prioritizing rapid, effective fire control, these Low Expansion Foam Chambers offer a proven solution, combining durability, performance, and adaptability across varied operational needs.
Products Parameters
|
Model Number |
Type |
Flow Rate |
Inlet Size |
Outlet Size |
|
PCL4 |
Low Expansion,vertical |
240LPM |
50mm(2'') |
80mm (3'') |
|
PCL8 |
Low Expansion,vertical |
480LPM |
65mm(2.5'') |
100mm(4'') |
|
PCL16 |
Low Expansion,vertical |
960LPM |
80mm (3'') |
150mm(6'') |
|
PCL24 |
Low Expansion,vertical |
1440LPM |
100mm (4'') |
200mm (8'') |
Products Features
| Body Material |
Carbon Steel; |
| Working Pressure Range |
0.3-0.6MPa; |
| Expansion | Low expansion,≥5 Times; |
| 25% Liquid Drain Time | ≥ 120 s; |
|
Flange Standard of Proportioner |
ANSI / BS4504 / GB; |
| Surface Finishing | Painting |
Products Description




Products Detailed

FAQ
Q: How to determine the correct Low Expansion Foam Chamber model for a storage tank?
A: Select based on the tank's required flow rate and piping dimensions. Match the model's LPM (e.g., PCL4 for 240 LPM) to the fire - suppression design, and ensure inlet/outlet sizes align with existing pipes. Larger tanks or higher - risk applications may require models like PCL24 (1440 LPM).
Q: Can Low Expansion Foam Chambers be used in marine (saltwater) environments?
A: While carbon steel resists general corrosion, saltwater exposure accelerates rusting. Apply marine - grade anti - corrosion coatings (e.g., zinc - rich epoxy) and conduct bi - annual inspections to maintain integrity.
Q: What is the impact of using non - standard flanges with these chambers?
A: Non - standard flanges (not BS4504/GB) may cause leaks or misalignment, reducing pressure stability and foam generation. Always use compatible flanges to ensure system safety and performance.
Q: How to test the expansion ratio of Low Expansion Foam Chambers in the field?
A: Conduct a flow test: measure the foam output volume against the input liquid volume. The ratio should be ≥5. Use a calibrated container to capture foam and liquid, then calculate expansion as (foam volume / liquid volume).
Q: What maintenance is required for Low Expansion Foam Chambers during idle periods?
A: Drain residual liquid every 3 months to prevent stagnation - related corrosion. Inspect internal components for debris or blockages, and verify flange seals remain intact. Perform a full system test annually.