The foinbo® Water Foam Cannon, part of the FM_B SERIES, is a sophisticated firefighting device designed to handle a wide range of fire - fighting situations with remarkable efficiency.
Send Inquiry
Description
Technical Parameters

Production introduction

 

The monitor nozzle is made of SS304 stainless steel, which is highly durable and can withstand the high - pressure flow of water and foam. The handle, also constructed from SS304 stainless steel, offers a firm and comfortable grip for firefighters operating the Water Foam Cannon.


A key feature of the foinbo® Water Foam Cannon is its ability to produce both straight steam and foam. This dual - functionality makes it highly versatile. The straight - steam mode is ideal for reaching distant fires and penetrating through thick flames, while the foam mode is effective in smothering fires, preventing reignition, and cooling down hot surfaces.


The FM_B SERIES offers several models, including FM 8/24B, FM 8/32B, FM 8/40B, and FM 8/48B. The FM 8/24B has a flow rate of 1440 L/Min, operating at a working pressure of 8 bar with a water maximum reach of 50 meters and a foam maximum reach of 42 meters. The FM 8/32B has a flow rate of 1920 L/Min, also at 8 bar, with a water maximum reach of 55 meters and a foam maximum reach of 48 meters. The FM 8/40B provides a flow rate of 2400 L/Min, operating at 8 bar, with a water maximum reach of 60 meters and a foam maximum reach of 55 meters. The FM 8/48B has the highest flow rate of 2880 L/Min, at 8 bar, with a water maximum reach of 65 meters and a foam maximum reach of 60 meters. All models are equipped with a 4 - inch/DN100 inlet flange compliant with BS4504, ensuring easy connection to water and foam supply systems.

 

Products parameters

 

Model Number

Flow Rate

W.Pressure

Max. Water Reach

Max. Foam Reach

Inlet Flange

FM 8/24B

1440 L/Min

8 bar

50 meters

42 meters

4 inch/DN100 @ BS4504

FM 8/32B

1920 L/Min

8 bar

55 meters

48 meters

4 inch/DN100 @ BS4504

FM 8/40B

2400 L/Min

8 bar

60 meters

55 meters

4 inch/DN100 @ BS4504

FM 8/48B

2880 L/Min

8 bar

65 meters

60 meters

4 inch/DN100 @ BS4504

 

FAQ

 

Q: How do I switch between the straight steam and foam functions of the foinbo® Water Foam Cannon?

A: Switching between the straight steam and foam functions of the Water Foam Cannon typically involves a two - step process. First, you need to connect or disconnect the foam supply line as per the manufacturer's instructions. Then, there may be a control mechanism on the cannon, such as a valve or a switch, that allows you to select the desired mode. Refer to the user manual for detailed and specific steps to ensure a smooth transition between the two functions.

Q: Can the foinbo® Water Foam Cannon be used in fires involving flammable liquids?

A: Yes, the Water Foam Cannon is highly effective in combating fires involving flammable liquids. When in foam mode, it can smother the flames by creating a blanket of foam over the liquid surface, cutting off the oxygen supply and preventing the fire from spreading. However, it's important to use the appropriate type of foam concentrate recommended by the manufacturer for optimal results and to follow all safety procedures when dealing with flammable liquid fires.

Q: How often should I inspect and maintain the foinbo® Water Foam Cannon?

A: Regular inspection and maintenance of the Water Foam Cannon are crucial for its optimal performance. After each use, it should be thoroughly cleaned to remove any foam residue and debris. Check the red epoxy powder coating for any signs of damage, such as chips or cracks, and repair them promptly. Inspect the nozzle for blockages or wear, and lubricate the moving parts as per the manufacturer's recommendations. Additionally, perform a more in - depth inspection at least once a month, including checking the integrity of the stainless - steel components and the functionality of the control mechanisms.

Q: What factors should I consider when choosing a model of the foinbo® Water Foam Cannon?

A: When choosing a model of the Water Foam Cannon, consider the size and intensity of the potential fires. If you expect to deal with larger fires over a greater area, a model with a higher flow rate and longer reach, such as FM 8/48B, would be more suitable. Also, take into account the available water and foam supply capacity at your disposal. Ensure that the model you choose can operate effectively within the limitations of your water and foam supply systems. Additionally, consider the typical fire scenarios in your area, whether they are industrial fires, urban building fires, etc., to select the most appropriate model for your specific needs.

Q: Can the foinbo® Water Foam Cannon be connected to a non - standard water supply system?

A: The Water Foam Cannon has a 4 - inch/DN100 inlet flange compliant with BS4504, which is a standard size. While it is designed to be connected to standard water supply systems, it may be possible to adapt it to non - standard systems with the use of appropriate adapters. However, this should be done with caution. You need to ensure that the water pressure and flow rate requirements of the cannon can still be met. It's advisable to consult the manufacturer or a professional in the field before attempting to connect it to a non - standard water supply system to avoid any potential issues that could affect the performance of the cannon.

 

Hot Tags: water foam cannon, China water foam cannon manufacturers, suppliers, factory, Jet Stream Water Cannon, Wheeled Fire Monitor, Cast Iron Flanged Y strainer, dry fire sprinkler, Flange Fire Hydrant, Check Valve Disc